15A ncac 02T .1206       SETBACKS

For areas for the storage of CCPs and sites where CCPs are used for structural fill and bedding, where the bedding is applied at a depth greater than two feet underneath the structure, the following minimum setbacks (i.e., in feet) shall be adhered to:

Private or public water supply sources                                                                            100

Surface waters (streams - intermittent and perennial, lakes,

                perennial waterbodies, and wetlands)                                                             50

Wells with exception to monitoring wells                                                                        100

Seasonal high water table                                                                                                  2

All distances are horizontal distances except for the distance from a seasonal high water table which is a measured as a vertical distance.

 

History Note:        Authority G.S. 143-215.1; 143-215.3(a);